| Fix merged | Fix | A nerve block billed on the other side from the surgery now asks a coder | No version | No ticket | Not released yet |
| Released | Fix | Automated claim validation keeps the side of service that the record documents | No version | No ticket |
Work that is planned, in progress, or merged and waiting for a production deploy. It is not released yet.
Work processed after carries this change.
When a nerve-block line carries RT or LT and the surgery is on the other side, the claim now carries the Compliance alert "ClaimCleaner Question: Block and Surgery Name Different Sides" (severity 5) for a coder. Before this change the difference was recorded on the claim and no one was asked.
How the side of the surgery is read. The autocoder compares the block's side modifier with the side of the primary anesthesia line: the side of its first-listed diagnosis (the reason for the surgery) and the line's own RT or LT. A sided condition that is not the reason for the surgery, such as a knee implant on a hernia repair, is never compared. A bilateral diagnosis covers both sides.
What the autocoder does not do. It never changes the side of the block or the side of the diagnosis. Both come from the record, and the two parts of the record disagree, so the coder reads the block note and the operative record and queries the provider when the record does not agree with itself (ICD-10-CM Official Guidelines I.B.14).
Example. A right knee replacement with M17.11 and an adductor canal block documented on the left: the claim bills 01402 and 64447-LT, keeps both sides as documented, and asks the coder which side the record supports.
How often. On a real set of 2,336 claims sent with no one touching them, the check fired on none, so a claim that gets this alert is rare and worth the look.
Anesthesia claims only. Your organization can silence the alert or send it to another reviewer role with the review-alert routing settings.
Automated claim validation (ClaimCleaner) checks the side of service on each line: the RT and LT modifiers, and the side in each diagnosis code. Validation now changes the right or left side only when the line documents that side, with one exception below. The sides that a line documents are the sides of its diagnosis codes and of its RT, LT or 50 modifier.
For example: an interventional radiology claim bills a thrombectomy of the right leg veins (37187) with I82.411 and I82.421 (right femoral and right iliac vein thrombosis) and no side modifier. Validation adds RT and keeps both right-side codes.