Every release and every piece of in-flight work for Medical Auto Coding. Filter by status, kind, or tag, then read the full notes below.
Showing the 100 most recent releases. Subscribe to the RSS feed for the full history.
Work that is planned, in progress, or merged and waiting for a production deploy. It is not released yet.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
Work processed after carries this change.
The encounter summary that the autocoder writes for each claim no longer
raises review alerts of its own. The three alert ids
anes_encounter_summary_flagged, radiology_encounter_summary_flagged and
eandm_encounter_summary_flagged are retired.
Each fact the summary could name has its own check: a missing patient name raises a data entry hold, and the other patient and place-of-service fields raise one when your configuration lists them as required; a missing provider raises a provider alert; a diagnosis concern raises a diagnosis validation alert. On radiology claims the summary step had raised a coder hold on every claim whose record carried no patient age or sex, a fact your required-field configuration decides. Those claims now proceed, with whatever holds your configuration asks for.
If an integration lists, routes on or reports these three ids, drop them.
Any issue text the summary step still produces is kept on the claim under
encounter_summary_issues for audit.
A diagnosis code that is not billable for the date of service no longer reaches your claim. The autocoder reads the record for the specific code. A coder is asked only when the record does not state it, and only when the claim needs the code.
A parent code, for example E11 (type 2 diabetes mellitus) or M10.0 (idiopathic gout), is not billable on its own. Payers reject a claim that carries one. For dates of service on or after October 1, 2026, ICD-10-CM fiscal year 2027 also makes some codes parent codes, for example I42.0 (dilated cardiomyopathy) and Z68.1 (BMI 19.9 or less, adult). This change applies to anesthesia, surgery, E/M and radiology claims.
When a diagnosis is a parent code, the diagnosis check now receives the billable codes of that family and selects the code that the record supports:
The autocoder never selects a code more specific than the record states.
The primary diagnosis is the reason for the surgery or the procedure (ICD-10-CM IV.A.1 and IV.N). The autocoder now reads it from the first of these that states one: the surgeon's postoperative diagnosis, then the diagnosis on the anesthesia record, then the preoperative diagnosis. A problem list or a past medical history never outranks them. For example, the preoperative diagnosis is "right lower quadrant pain", the postoperative diagnosis is "acute appendicitis", and the problem list names hypertension. The primary diagnosis is acute appendicitis (K35.80). When several procedures are done under one anesthetic, the primary diagnosis is the reason for the procedure that the billed anesthesia code covers (the highest-base-unit procedure); the reasons for the other procedures are secondary, subject to ICD-10-CM sequencing rules. Conflicting documentation that does not establish the reason is a question for a coder, not an automatic choice. For example, a laparoscopic cholecystectomy with an umbilical hernia repair under one anesthetic bills 00790; the primary diagnosis is the cholecystitis, and the hernia is secondary. For a visit or a post-operative pain round, the primary diagnosis is the reason for that service.
Hank's rule: a comorbidity is coded when the record documents it as a current condition that affects the care in this encounter (ICD-10-CM IV.I and IV.J). A medication or treatment counts as support only when the record ties it to the condition (OSA on CPAP, type 2 diabetes on metformin); a medication list alone does not make a condition current. A chronic condition in the pre-anesthesia evaluation counts as current unless the record marks it resolved. A resolved condition gets a history code only when that history still affects the care. For example, "OSA, uses CPAP" is coded, and "pneumonia last spring, resolved" is not.
See the Anesthesia Alert Reference and Diagnosis Coding for the triggers and what to verify.
Two radiology checks read the official title of a diagnosis code: the check that keeps a diagnosis on the side the report documents, and the check that compares the spine region of the study with the spine region of the diagnosis. Both checks now read that title for the fiscal year of the date of service, wherever your claims are coded.
Sides. On a bilateral study, a diagnosis that names one side (a cyst of the left breast, for example) goes on the line for that side only. A diagnosis that names no side goes on both lines, as before. When claim validation adds a diagnosis for the other side that the report does not document, the autocoder removes it.
Spine level. When the study covers one spine region and the diagnosis names a different region (a cervical MRI with a lumbar stenosis code), the Spine ICD Level Differs from Documented Level alert (Compliance, severity 7) asks a coder to confirm the diagnosis. In HANK Claim Maker, a Compliance alert for a coder places the claim in the review queue that your administrators configured for it.
Nothing changes in what you configure.
The radiology autocoder now follows the ICD-10-CM Tabular List titles and the Alphabetic Index for the findings below. The codes come from the code set of the fiscal year of the date of service. The examples use fiscal year 2026 codes.
Breast density. Each density category has its own code family. Fatty tissue density is R92.31-. Fibroglandular density is R92.32-. Heterogeneous density is R92.33-. Extreme density is R92.34-. The last character gives the side: 1 is the right breast, 2 is the left breast and 3 is both breasts. For example, "extremely dense breasts" on both sides is R92.343. A report that says only "dense breasts", with no density category, is R92.30.
Other mammography findings. Microcalcification is R92.0. Calcification that the report does not call micro is R92.1. ICD-10-CM has no code of its own for asymmetry or for architectural distortion. These findings are R92.8, as in the Index ("Findings, abnormal, mammogram NEC").
Breast lumps on ultrasound. Each quadrant has its own code. The clock position maps to the quadrant as the radiologist sees the patient. In the right breast, 1 to 3 o'clock is upper inner and 9 to 11 o'clock is upper outer. The left breast is the mirror image. For example, a right breast lump at 4 o'clock (lower inner quadrant) is N63.14. A lump that covers more than one quadrant is N63.15 (right) or N63.25 (left). A subareolar lump is N63.41 (right) or N63.42 (left). N63 has no bilateral code, so lumps in both breasts get right breast codes and left breast codes (Official Guidelines I.B.13). Each lump gets the code of its location: a quadrant, subareolar or axillary tail code. R92.8 can apply to breast ultrasound as well as to mammography. A lump with a known location takes its N63 code.
Cough. Acute cough is R05.1. Chronic cough is R05.3. A report that says only "cough" stays R05.9.
Pulmonary embolism. The level of the clot (main, lobar, segmental) does not select the code. An I26.0- code (with acute cor pulmonale) needs documented acute cor pulmonale. A subsegmental clot without acute cor pulmonale is I26.93 (single) or I26.94 (multiple). On CT of the chest with contrast (71260) and CT angiography of the chest (71275), the autocoder can now select each code in ICD-10-CM category I26 (pulmonary embolism) that is valid on the date of service. For example, a saddle embolus without acute cor pulmonale is I26.92, as in the Index ("Embolism, pulmonary, saddle"). When the embolus is the finding that explains the reason for the exam, I26.92 is the first-listed code. The Low Confidence Primary ICD (Radiology) alert (Compliance, severity 7) can ask a coder to confirm I26.92 as the first-listed code.
First-listed diagnosis with a billing-history setting. Some organizations use a setting that comes from their billing history. With this setting, a code that the organization never billed first for the exam becomes a secondary code. The setting does not apply to the code of a definite finding in the impression that answers the reason for the exam. The FY2026 Official Guidelines (Section IV.K) list first the condition that is chiefly responsible for the exam. They also tell the coder to code the confirmed diagnosis in the report, and not the related symptoms. For example, a CT angiogram of the chest for shortness of breath shows a saddle pulmonary embolus and a small pleural effusion. The claim lists I26.92 first and J90 second.
Enlarged brain ventricles. On a head CT or a brain MRI, ventriculomegaly is an imaging finding. Its code is R90.89, as in the Index ("Abnormal, diagnostic imaging, central nervous system NEC"). The Index has no entry for ventriculomegaly. The autocoder uses a hydrocephalus code (G91.-) only when the report states hydrocephalus.
Gallbladder polyp. A gallbladder polyp is K82.4, as in the Index ("Polyp, gallbladder"). The Tabular title of K82.4 is "Cholesterolosis of gallbladder". The Index sends a gallbladder polyp to this code.
Rib pain on a rib X-ray. Rib pain is R07.89, as in the Index ("Pain, rib"). R07.81 (pleurodynia) applies when the report states pleuritic pain, pleurodynia or pleuralgia. Pleurisy is R09.1. Pain on breathing is R07.1. An organization configuration that sets its own rib pain convention still applies.
Pregnancy on obstetric ultrasound. A pregnancy code (O00-O9A) keeps its first-listed place on an obstetric ultrasound claim, ahead of the weeks-of-gestation code (Z3A). The exam region does not remove a pregnancy code. The FY2026 Official Guidelines give chapter 15 codes sequencing priority (Section I.C.15.a.1). The Tabular note at Z3A tells the coder to code first the obstetric condition.
What to look out for. On breast, chest, brain, gallbladder, obstetric and rib imaging claims, expect the codes above. An organization configuration that sets its own convention for one of these codes still applies. Nothing changes in what you configure. No alert is added or removed. The Low Confidence Primary ICD (Radiology) alert can show on more pulmonary embolism claims, because I26.92 can now be the first-listed code. In HANK Claim Maker, a Compliance alert for a coder places the claim in the review queue that your administrators configured for it.
On low-dose CT lung cancer screening (CPT 71271), the autocoder adds the patient's tobacco-status diagnosis as a secondary code when the report documents it. Medicare (NCD 210.14) denies a 71271 line that does not carry one of six codes: Z87.891, F17.210, F17.211, F17.213, F17.218 or F17.219.
The accepted code comes first. When the report supports more than one tobacco-status code, the autocoder now picks a code from the Medicare list before any other tobacco code, even when the autocoder is more confident in the other code. The evidence for the listed code must be strong: the autocoder does not pick a listed code on weak evidence only to pass the Medicare edit.
Other tobacco codes stay, with a note. When the report documents only a tobacco code that is not on the list (for example F17.200, nicotine dependence with an unspecified product), the autocoder still codes it. The line rationale then says that a Medicare 71271 line with only that code will deny, so your coders can check the documentation for the product type.
What to look out for: the rationale text on the tobacco line of a 71271 claim now names the Medicare list. No new review alert is raised.
Procedure descriptions now follow the date of service. When the autocoder weighs a CPT code, it reads the official description of that code. It now reads the description for the year of the date of service. Before this change, it could read a description from an older code set year when that older text was longer.
For most codes the text is the same in every year, so you see no change. For a small set of codes the older text was worded differently. One example is 43264 (ERCP with removal of stones or debris): the current description names both the biliary and the pancreatic ducts, and the autocoder now reads that description.
What to look out for: nothing changes in your configuration. Anesthesia cases that crosswalk from these procedures now see the current description when the autocoder selects the anesthesia code.
Automated claim validation (ClaimCleaner) checks the side of service on each line: the RT and LT modifiers, and the side in each diagnosis code. Validation now changes the right or left side only when the line documents that side, with one exception below. The sides that a line documents are the sides of its diagnosis codes and of its RT, LT or 50 modifier.
For example: an interventional radiology claim bills a thrombectomy of the right leg veins (37187) with I82.411 and I82.421 (right femoral and right iliac vein thrombosis) and no side modifier. Validation adds RT and keeps both right-side codes.
Radiology coding gains a set of denial-safety checks. Your account team turns each one on for you; nothing changes until they do.
No more empty claims. Three separate causes let a claim leave with no diagnosis or no line item: a trauma study with a negative report, a screening tomosynthesis add-on coded without its base mammogram, and a diagnosis the coder named correctly but at a category level that cannot be billed. Each is fixed: the trauma encounter code is applied, the base mammogram line is added, and a category code is resolved to its billable child that matches the report.
Procedure codes that do not exist are repaired before diagnoses are chosen. When the selected procedure code is not in the code set for the date of service, the autocoder tries, in order, your configured successor code, the exam code printed in the report header, and a pick among the code's own family by description. Every repair is recorded as a review alert. A code that cannot be repaired stops the claim for a coder instead of denying at the payer.
The exam code printed in the report is read and checked. When a report prints its exam code and no line on the claim carries it, the claim is flagged; you can choose to have single-line claims adopt the printed code.
Sides are protected. When the report names a side, the autocoder no longer lets a more frequently billed "bilateral" or opposite-side code replace it.
Screening studies lead with the screening diagnosis. A study the report classifies as a screening (for example a coronary calcium score for risk stratification) is coded with your screening diagnosis first and any incidental finding second, as the ICD-10-CM guidelines require.
An audit verdict on every claim (optional). Each finished claim can carry a denial-safety verdict: a pass or fail checklist of fifteen ICD-10-CM rules, flags for diagnoses the report does not state in words, a confidence score, a denial-risk level, and a two-to-four sentence explanation written for your coders. The Excludes1 and "code first" rules of the checklist read the ICD-10-CM notes for the fiscal year of the date of service. When those notes are not available, the verdict lists the two rules as not checkable. If your organization receives the claim data through the coding API, the verdict is in the claim metadata field radiologyAudit.
What to look out for: three new review alerts.
A review of the whole radiology coding path found a number of rules that were removing correct codes or adding incorrect modifiers. They are corrected.
Findings from the imaged area are no longer discarded. A safety check drops diagnoses that do not belong to the body part a study covers. Its list of body parts was incomplete, so it discarded findings it should have kept: cardiomegaly on a chest study, an abdominal aortic aneurysm or a kidney tumor on an abdominal CT, sciatica on a lumbar spine study, a calcaneal spur on a foot film, and a shoulder fracture on a trauma CT of the chest. It also let a few codes for other body parts through, such as bursitis of the hand on a shoulder study. Both directions are fixed.
Two codes that differ by level or type are no longer treated as left and right. One check read the last digit of a code as the side of the body and removed one of two codes it believed contradicted each other. For many code families that digit means something else, so it removed, for example, the second disc level of a two-level cervical disc disorder. It now uses the official code title and only removes a genuine opposite-side duplicate.
Professional and technical component modifiers follow the fee schedule. Modifier 26 was applied to every diagnostic radiology code on professional claims. A small group of codes, such as trabecular bone score (77089), has no professional or technical split, and the modifier would cause a denial. It is no longer added to those codes, and it is removed where another step added it.
Other corrections. A report header that prints a code deleted in a previous year is no longer adopted over a valid code. A both-knees standing study is no longer split into a right and a left line. PET studies receive the PI or PS modifier only when there is an oncologic reason for the study. A mammography mass is coded to "other abnormal findings" rather than to a calcification code. Observation codes are removed when a related symptom is coded. A fracture code missing its seventh character receives it instead of being dropped.
What you will see. Most claims are unchanged. On 600 randomly drawn studies, 45 claims changed codes, usually by keeping one additional documented finding. Each changed claim was reviewed against its report: the new coding was better on 27, equivalent on 6, and worse on 3. On the remaining 9 both versions had an error the change did not touch, and the new version was closer on most of them. The 3 that got worse exposed a separate issue in how the leading diagnosis is chosen, and that issue remains open.
Two corrections to how diagnoses are chosen on radiology claims. Your account team turns the first one on for you; the second applies wherever it is relevant.
The claim keeps the finding the study was done to answer. Several checks run after a diagnosis is chosen, and each of them can remove a code: one re-examines whether the report supports it, another restores a known condition the referring physician named. In rare combinations these ran in sequence and removed every code for the thing the radiologist actually reported, leaving a claim that described only incidental findings. On a surveillance scan ordered to look for recurrent disease, the enlarged lymph nodes the radiologist called out disappeared and a hiatal hernia was left as the first diagnosis.
The autocoder now checks, at the end, that at least one diagnosis on the claim comes from the impression finding that answers the reason for the exam. If none does, that finding is added back. It is added as a secondary diagnosis and does not displace the diagnosis your coders would expect to lead, except when the leading code is a purely incidental finding, in which case the reason for the exam takes its place. Only findings the extraction was confident about are added back, so hedged observations are not turned into diagnoses.
A cancer of an organ that has been removed is no longer billed as current. When a report documents that an organ was surgically removed and the patient's history names a cancer of that organ, the correct code is the personal-history code, not a current malignancy. The autocoder makes that substitution only when the record proves the whole site is gone: both breasts, both ovaries, a hysterectomy, or a mastectomy on the same side as the coded cancer.
Everywhere else it deliberately does not decide for you. A partial resection of lung, stomach or bowel, or an absence code that does not say which side, leaves the current cancer code exactly as it was and raises a review alert explaining the choice: if the tumour site is gone and no treatment is directed to it, use the personal-history code named in the alert; if the cancer is in the tissue that remains, the current code is already right. A cancer in the organ the patient still has is not flagged at all.
Two diagnosis tables were corrected against the official code set. A sweep of every diagnosis and procedure code written into the autocoder found a mapping that turned one hip condition into another. When a hip study is bilateral and the radiologist documented arthritis of only one side, the autocoder upgrades the diagnosis to its bilateral form. For hips it was upgrading to the wrong form: arthritis caused by hip dysplasia became post-traumatic arthritis, and post-traumatic arthritis became "other secondary". Both now map to the correct bilateral code, so the claim no longer asserts an injury the report does not describe. A second table, the one that decides which diagnoses belong to which body region, carried entries for codes that do not exist and three codes that mean "site unspecified" but were listed as if they named a joint. Both are corrected, and a new automated check refuses any code written into the autocoder that does not exist in the code set.
What you will see. On affected claims, one additional diagnosis that was previously dropped, and a new review alert where a current cancer sits beside evidence that the organ was removed. On a sample of 300 randomly drawn studies, 18 claims changed; procedure codes were unaffected.
Modifiers 59, XE, XS, XP, and XU exist for one purpose: to bypass a Medicare NCCI edit between two codes on the same claim. When no edit exists, the codes pay separately on their own and the modifier is unnecessary. Payers flag unnecessary distinct-service modifiers in audits.
Before this change, the autocoder sometimes placed one of these modifiers on a code pair that has no NCCI edit. Example: a diagnostic cervicocerebral angiogram that bills carotid angiography (36224) and vertebral angiography (36226) together. Medicare holds no edit between those codes, so no modifier is needed, but an XS could still appear on the vertebral line.
Now the autocoder checks the licensed NCCI edit table at claim build. If a line carries 59 or an X modifier and no edit pairs its code with any other code on the claim, the modifier is removed. The claim carries an informational note, "Distinct-Service Modifier Removed (No NCCI Edit)", as an audit trail. No action is needed.
The check is careful in three ways. A modifier on a real edit pair is never touched. A modifier on a repeated code (the same code on two lines) is never touched, because it can mark a separate encounter. And when the NCCI data is not available in a deployment, nothing is removed.
A related alert also improved. The "may need distinctness modifier" review alert used to appear on every claim with two or more procedures. It now appears only when a real NCCI edit pairs the codes, so it no longer asks your team to add a modifier the claim does not need.
Reference material now matches the date of service. When the autocoder looks up code reference material while it codes a case, it reads only the reference set for the claim's date of service. CPT references follow the calendar year. Diagnosis references follow the October to September fiscal year. Before this change, a case coded for an earlier date of service could see current year material.
This matters most on back dated work: a claim for a service in a prior year is now coded against the code set that was in force on that date, not against the current one.
What to look out for: back dated cases should select codes that were valid on the date of service. When a case carries no date of service, the autocoder still reads every year, as it did before. If a claim needs the date of service to be right for this reason, confirm the date before you reprocess the case.
This release fixes a customer-reported problem with the extreme-age add-on code 99100 and tightens several related checks.
99100 now anchors to the date of service. The autocoder decides the extreme-age add-on (99100) from the patient's age ON THE DATE OF SERVICE. The date the case is processed no longer matters. Before this fix, a re-run of an unchanged case after the patient's 70th birthday could add 99100 that the first run correctly omitted. That cannot happen now.
Every 99100 is verified against the ASA age rule. The patient must be younger than 1 year, or at least 70 years and 1 day old, on the date of service. The 70th birthday alone does not qualify. A 99100 that qualifies is billed and gets the new alert "Extreme-Age Add-On 99100 Billed (Age Verified on Date of Service)" so a coder can confirm the demographics. A 99100 that does not qualify, or whose age cannot be verified, is kept on the claim for review and is not billed. Two new alerts name those outcomes.
What to look out for: claims for patients near their 70th birthday. A patient who turns 70 AFTER the date of service does not get 99100, even when the case is coded weeks later. This is correct and intended.
The anesthesia coder can now decline an unsupported code. When the documentation supports none of the candidate anesthesia codes, the autocoder returns no code and the claim is held for human review. It is no longer forced to pick the closest candidate. A new alert, "Anesthesia Code Cites Only Plan/History Documentation", also fires when a billed anesthesia code rests only on the pre-anesthesia evaluation although the record contains procedure documentation.
Anesthesia times now appear on more claims. When the billed anesthesia time comes from provider coverage times because the chart has no discrete anesthesia start and stop, the claim's anesthesia times field now shows the times that were billed. Those claims previously billed correctly but showed empty anesthesia times.
Contrast supply codes corrected (radiology). Q9968 and Q9969 are no longer treated as contrast agents. Q9968 is a visualization adjunct such as methylene blue. Q9969 was retired from HCPCS at the end of 2025. The high-osmolar contrast family Q9958 through Q9964 is now recognized for wastage checks alongside the low-osmolar family Q9965 through Q9967.
This release makes the data the autocoder sends to the automated claim validation service (ClaimCleaner) truthful in every field. Validation verdicts become more accurate. Nothing about this change requires action on your side, with one new alert to know about.
A claim without a date of service is no longer validated against a guessed date. Before this release, when no date of service could be found in the record, the validation step silently used the processing date instead. Every date-anchored check (code validity for the year, coverage windows, unit limits) then ran against a wrong date. Now the autocoder raises the new alert "Date of Service Could Not Be Resolved - Validation Skipped" (HARDSTOP) and skips validation. Supply the date of service and reprocess; validation then runs normally. Typical handling in HANK Claim Maker: the claim is held until a reviewer resolves the alert.
Patient age now reaches validation. The validation service checks billed codes against age rules (newborn, pediatric, maternity, adult). Before this release, the patient's age almost never reached it. Now the age is sent whenever a true date of service exists: computed from the date of birth when the record has a usable one, or taken from the documented age otherwise. A date of birth that cannot be true (for example, a date after the service) is never turned into an age. The age is always the age ON the date of service, never the age on the day the case was processed.
Coverage checks can now use your real service location. Medicare coverage rules differ by region. Before this release, the claim's location came from the insurance company's mailing address, which selected the wrong region or none at all. That address is no longer used. Your HANK representative can now configure your facility's real service location, and coverage checks then run against the correct regional rules. Expect some validation findings to change on claims that previously matched a wrong region: the new findings are the correct ones.
A refused validation connection now raises a critical alert. When the validation service refuses the connection because of a deployment problem (an expired token or an exhausted quota), every claim is affected until an administrator fixes it. Those claims now get the alert "ClaimCleaner Refused the Request" (HARDSTOP). A plain network hiccup keeps the existing lower-severity alert. Typical handling in HANK Claim Maker: the refused claims wait in the review queue until the deployment is fixed and the claims are revalidated.
What to look out for: claims with no date of service were already held for the missing date. What is new: the validation step no longer runs against a made-up date on those claims, and the new alert names exactly why validation was skipped. Supplying the date clears it and validation runs normally.
The autocoder applies its radiology claim rules again. A configuration defect switched off every radiology rule, so none of the radiology alerts could appear on a claim. The rules now load and run.
Add-on codes are checked on every radiology claim. When a claim carries an add-on code and none of the primary codes CMS accepts for that add-on, the claim carries the alert "IR Add-On Code Without CMS-Acceptable Primary". The alert names the acceptable primary codes. The check reads the CMS add-on code edit data. It stays silent when CMS defines no primary list for the add-on. This check runs on diagnostic radiology claims as well as interventional radiology claims.
The radiology bundling and documentation alerts can appear on any radiology claim whose codes match the rule, not only on interventional work. The July interventional radiology update lists those alerts by name.
What to look out for: expect these alerts on ordinary diagnostic radiology claims that never raised them before. The checks were not running at all, so a claim that passed clean last month can raise an alert this month. Your organization can ask your Hank representative to retune or switch off an individual radiology rule.
Radiology claims apply the component modifiers your configuration asks for. The rules that decide the professional component (modifier 26) and the technical component (modifier TC) read the billing component set for your organization. That setting stopped reaching the coding step, so the rules had nothing to act on, so no radiology claim received a component modifier from them. The setting is live again, and radiology coding follows it.
While the setting was not reaching the coding step, radiology claims were coded as if no component preference existed. Claims coded in that window may therefore be missing the modifier your configuration calls for. Check them before you submit them.
What to look out for: a radiology claim may now carry a 26 or a TC modifier where recent claims carried none. Check that the billing component configured for your organization matches how you bill: professional, technical, global, or split. Ask your Hank representative if the setting needs to change.